  1. Navien 240A not getting generating very hot water

    May 11, 2021 · Hello I have a Navien NPE 240A. About 6 yo. Propane. Re-circulation pump programed to run 5AM to 10PM. I clean the filters and de-scale annually. I'm seeing a variation of the issues …

  2. Navien NPE-240A NG Leaking - Love Plumbing & Remodel

    May 21, 2017 · My 2 yr-old Navien heater has apparently been leaking for quite some time. I removed the cover and noticed the top of the pump was leaking (where the red cap is) and the bottom of the …

  3. Navien NPE240A- Navilink,Navilink App, Recirculation settings And ...

    Jan 15, 2020 · Navien NPE 240A— Navilink recirculation—some customer insights. I have had The Navien NPE240A for about two years now and the unit has worked flawlessly, but it has taken me a …

  4. Navien NPE-240A - Temperature Fluctuations - Love Plumbing

    Mar 17, 2022 · I recently installed a Navien NPE-240A. The water temperature fluctuates 20 degrees when I take a shower. Navien currently does not have tech support for homeowners but I was able to …

  5. Navien NPE-210A2 vs NPE240A2 - Love Plumbing & Remodel

    Nov 15, 2023 · The plumber installed the wrong Navien tankless water heater. I asked for the NPE240A2, and he installed the NPE210A2. He says he can exchange but thinks the 210 is …

  6. Navien NCB-240 Combi Boiler - DHW is fine, NO HEAT

    Oct 5, 2022 · 2/2022 Partner replaced a 1969 American standard gas boiler and dying water heater with a Navien NCB 240 Combi Boiler. Heat was fine from Feb thru April...

  7. E010 on Navien with solution and report on my problems over 4 years

    Jul 9, 2015 · Ok, So I have a 4.5 year old Navien NR-210a condensing tankless heater. (Late 2010) I more or less did the entire install myself with the help of a few skilled friends either on site or on the …

  8. Navien 240A (Controlling the Circulation Pump) - Love Plumbing

    Feb 24, 2022 · Our 240A uses an External Recirculation Line and, at this time, we have no accessories, e.g., NaviLink, Remote Controller (NR-20DU) or HotButtons. Attached screenshot shows the …

  9. Navien 240a external recirculation settings with thermal comfort valve ...

    Sep 24, 2017 · The Navien itself is about as far away from the fixtures as possible. It's mounted outside close to the gas main in and replaced a tank water heater in the attic. With the external recirculation …

  10. I have problem with Navien NCB-190/060H Error Code E031-00

    Jan 28, 2025 · NAVIEN NCB-150E SERVICE MANUAL Pdf Download View and Download Navien NCB-150E service manual online. NCB-E Condensing Water Heaters. NCB-150E water heater pdf manual …